AD 15 / ADI 15 / ADT 15
Flow switches
Series
Mounting instructions
AD-15
ADI / ADT-15
Working principle
Series AD-15, ADI-15, ADT-15
If a fluid flows with enough flow rate through a metering
pipe A, with a mobile disc B and a calibrated spring C,
the disc will be displaced.
The distance depends on:
The flow rate F.
The relation between the areas A and B.
The opposing force of the calibrated spring C.
The equilibrium of the forces defines the position of
the calibrated disc B, and at the same time, the flow
rate.
The calibrated disc B has a magnet M. The magnetic
field acts on the alarms, the indicator or the transmitter.
A = Metering tube
B = Calibrated metering disc
C = Calibrated spring
F = Flow rate
M = Magnet
C-MI-AD15 Rev.:1
English version
A
B
C
M
F
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - Mounting instructions

AD 15 / ADI 15 / ADT 15 Flow switches Series Mounting instructions AD-15 ADI / ADT-15 Working principle Series AD-15, ADI-15, ADT-15 If a fluid flows

Strona 2

Technical data Series AD-15, ADI-15, ADT-15 • Accuracy: ± 5% of full scale. • Measuring range: 10:1,6 • Disc displacement: 40mm ± 5

Strona 3

Install the flow rate detector in a pipe, with the arrow in the fluid direction. For the electrical installation, a multi-conductor cable should be us

Strona 4